Contact me immediately if you encounter problems!

All Categories

Damper

Combination Damper-LZFDF: Duct sizes 2000×2000 to 8000×8000 mm. Manual or electric actuator. Galvanized steel with silicone seals.

Fire Damper-FHF-WS: Sizes 120×120 to 2000×1250 mm. Fusible link + spring return. Corrosion-resistant steel.

Volume Damper-VCD: Sizes 120×120 to 2000×1500 mm. Manual quadrant or electric actuator. Galvanized steel.

Backdraft Damper: Sizes 200×200 to 2000×1250 mm. Gravity or counterweight. Aluminum or galvanized blades.

  • Overview
  • Product Advantages
  • Applications
  • FAQ
  • Recommended Products
Model Image Target Customers Core Advantages Core Keywords
Combination Damper-LZFDF _DSC7293.png Subway tunnels, central AC, ventilation networks, large building HVAC Multi-blade linkage; Tight sealing; Precise control; Rugged Volume control damper, multi-blade damper
Fire Damper-FHF-WS _DSC7211.png Shopping malls, hospitals, factories with fire safety Fuse link closure; Fire & smoke isolation; Strong sealing; Code-compliant Fire damper, smoke damper
Volume Damper-VCD _DSC7223.png Industrial plants, commercial buildings, computer rooms Manual/electric adjustment; Good sealing; Fits various ducts Volume damper, balancing damper
Backdraft Damper _DSC7252.png Fan outlets, exhaust pipes, HVAC ducts Reliable sealing; Simple structure; Low resistance Backdraft damper, check damper

Product Advantages

Combination Damper-LZFDF

• Opposed-blade for linear flow.
• Leakage ≤2% at 1000 Pa.
• Heavy-duty linkage.
• Flanged or slip-on.

Fire Damper-FHF-WS

• Fuse link at 70°C or 280°C.
• Blade seals limit smoke.
• Meets GB15930, UL555 optional.
• Manual reset after fuse replacement.

Volume Damper-VCD

• Manual or motorized.
• Blade edge seals reduce leakage.
• Cost-effective $11.5/m².
• Standard flanges.

Backdraft Damper

• Tight gravity closure.
• Low pressure drop when open.
• No springs/actuators.
• $14.2/m².

_DSC7295.png_DSC7291.png_DSC7193.png_DSC7209.png_DSC7223.png_DSC7214.png

Applications

Combination Damper-LZFDF: Main air ducts; tunnel ventilation control; industrial exhaust balancing; HVAC zone control.

Fire Damper-FHF-WS: Fire-rated duct penetrations; smoke exhaust; HVAC return; staircase pressurization.

Volume Damper-VCD: HVAC branch balancing; industrial exhaust; lab fume hood; computer room cooling.

Backdraft Damper: Fan discharge; exhaust louver; HVAC supply with multiple fans; AHU discharge.

_DSC7301.png_DSC7302.png_DSC7197.png_DSC7195.png_DSC7220.png_DSC7259.png

FAQ

Model: Combination Damper-LZFDF

Q1: What actuator voltage is available?
– 24V, 220V, or 380V.

Model: Fire Damper-FHF-WS

Q1: What temperature ratings are available?
– 70°C (fire) or 280°C (smoke).

Q2: Is an actuator included?
– Thermal actuator (fuse link) included; electric reset optional.

Model:VolumeDamper-VCD

Q1: What is the leakage class?
– Class 3 (standard) or Class 2 (with seals).

Q2: Can it be used in high-temperature air?
– Up to 150°C with special seals.

Model:Backdraft Damper (Check Valve)

Q1: Can it be installed horizontally?
– Yes, with spring assist.

Q2: What is the maximum velocity?
– 15 m/s.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000